123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146 |
- * Maxim MAX8997 Voltage and Current Regulator
- The Maxim MAX8997 is a multi-function device which includes voltage and
- current regulators, rtc, charger controller and other sub-blocks. It is
- interfaced to the host controller using a i2c interface. Each sub-block is
- addressed by the host system using different i2c slave address. This document
- describes the bindings for 'pmic' sub-block of max8997.
- Required properties:
- - compatible: Should be "maxim,max8997-pmic".
- - reg: Specifies the i2c slave address of the pmic block. It should be 0x66.
- - max8997,pmic-buck1-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
- units for buck1 when changing voltage using gpio dvs. Refer to [1] below
- for additional information.
- - max8997,pmic-buck2-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
- units for buck2 when changing voltage using gpio dvs. Refer to [1] below
- for additional information.
- - max8997,pmic-buck5-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
- units for buck5 when changing voltage using gpio dvs. Refer to [1] below
- for additional information.
- [1] If none of the 'max8997,pmic-buck[1/2/5]-uses-gpio-dvs' optional
- property is specified, the 'max8997,pmic-buck[1/2/5]-dvs-voltage'
- property should specify atleast one voltage level (which would be a
- safe operating voltage).
- If either of the 'max8997,pmic-buck[1/2/5]-uses-gpio-dvs' optional
- property is specified, then all the eight voltage values for the
- 'max8997,pmic-buck[1/2/5]-dvs-voltage' should be specified.
- Optional properties:
- - interrupt-parent: Specifies the phandle of the interrupt controller to which
- the interrupts from max8997 are delivered to.
- - interrupts: Interrupt specifiers for two interrupt sources.
- - First interrupt specifier is for 'irq1' interrupt.
- - Second interrupt specifier is for 'alert' interrupt.
- - max8997,pmic-buck1-uses-gpio-dvs: 'buck1' can be controlled by gpio dvs.
- - max8997,pmic-buck2-uses-gpio-dvs: 'buck2' can be controlled by gpio dvs.
- - max8997,pmic-buck5-uses-gpio-dvs: 'buck5' can be controlled by gpio dvs.
- Additional properties required if either of the optional properties are used:
- - max8997,pmic-ignore-gpiodvs-side-effect: When GPIO-DVS mode is used for
- multiple bucks, changing the voltage value of one of the bucks may affect
- that of another buck, which is the side effect of the change (set_voltage).
- Use this property to ignore such side effects and change the voltage.
- - max8997,pmic-buck125-default-dvs-idx: Default voltage setting selected from
- the possible 8 options selectable by the dvs gpios. The value of this
- property should be between 0 and 7. If not specified or if out of range, the
- default value of this property is set to 0.
- - max8997,pmic-buck125-dvs-gpios: GPIO specifiers for three host gpio's used
- for dvs. The format of the gpio specifier depends in the gpio controller.
- Regulators: The regulators of max8997 that have to be instantiated should be
- included in a sub-node named 'regulators'. Regulator nodes included in this
- sub-node should be of the format as listed below.
- regulator_name {
- standard regulator bindings here
- };
- The following are the names of the regulators that the max8997 pmic block
- supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number
- as per the datasheet of max8997.
- - LDOn
- - valid values for n are 1 to 18 and 21
- - Example: LDO0, LD01, LDO2, LDO21
- - BUCKn
- - valid values for n are 1 to 7.
- - Example: BUCK1, BUCK2, BUCK3, BUCK7
- - ENVICHG: Battery Charging Current Monitor Output. This is a fixed
- voltage type regulator
- - ESAFEOUT1: (ldo19)
- - ESAFEOUT2: (ld020)
- - CHARGER_CV: main battery charger voltage control
- - CHARGER: main battery charger current control
- - CHARGER_TOPOFF: end of charge current threshold level
- The bindings inside the regulator nodes use the standard regulator bindings
- which are documented elsewhere.
- Example:
- max8997_pmic@66 {
- compatible = "maxim,max8997-pmic";
- interrupt-parent = <&wakeup_eint>;
- reg = <0x66>;
- interrupts = <4 0>, <3 0>;
- max8997,pmic-buck1-uses-gpio-dvs;
- max8997,pmic-buck2-uses-gpio-dvs;
- max8997,pmic-buck5-uses-gpio-dvs;
- max8997,pmic-ignore-gpiodvs-side-effect;
- max8997,pmic-buck125-default-dvs-idx = <0>;
- max8997,pmic-buck125-dvs-gpios = <&gpx0 0 1 0 0>, /* SET1 */
- <&gpx0 1 1 0 0>, /* SET2 */
- <&gpx0 2 1 0 0>; /* SET3 */
- max8997,pmic-buck1-dvs-voltage = <1350000>, <1300000>,
- <1250000>, <1200000>,
- <1150000>, <1100000>,
- <1000000>, <950000>;
- max8997,pmic-buck2-dvs-voltage = <1100000>, <1100000>,
- <1100000>, <1100000>,
- <1000000>, <1000000>,
- <1000000>, <1000000>;
- max8997,pmic-buck5-dvs-voltage = <1200000>, <1200000>,
- <1200000>, <1200000>,
- <1200000>, <1200000>,
- <1200000>, <1200000>;
- regulators {
- ldo1_reg: LDO1 {
- regulator-name = "VDD_ABB_3.3V";
- regulator-min-microvolt = <3300000>;
- regulator-max-microvolt = <3300000>;
- };
- ldo2_reg: LDO2 {
- regulator-name = "VDD_ALIVE_1.1V";
- regulator-min-microvolt = <1100000>;
- regulator-max-microvolt = <1100000>;
- regulator-always-on;
- };
- buck1_reg: BUCK1 {
- regulator-name = "VDD_ARM_1.2V";
- regulator-min-microvolt = <950000>;
- regulator-max-microvolt = <1350000>;
- regulator-always-on;
- regulator-boot-on;
- };
- };
- };
|