1234567891011121314151617181920212223242526272829 |
- ARM sp804 Dual Timers
- ---------------------------------------
- Required properties:
- - compatible: Should be "arm,sp804" & "arm,primecell"
- - interrupts: Should contain the list of Dual Timer interrupts. This is the
- interrupt for timer 1 and timer 2. In the case of a single entry, it is
- the combined interrupt or if "arm,sp804-has-irq" is present that
- specifies which timer interrupt is connected.
- - reg: Should contain location and length for dual timer register.
- - clocks: clocks driving the dual timer hardware. This list should be 1 or 3
- clocks. With 3 clocks, the order is timer0 clock, timer1 clock,
- apb_pclk. A single clock can also be specified if the same clock is
- used for all clock inputs.
- Optional properties:
- - arm,sp804-has-irq = <#>: In the case of only 1 timer irq line connected, this
- specifies if the irq connection is for timer 1 or timer 2. A value of 1
- or 2 should be used.
- Example:
- timer0: timer@fc800000 {
- compatible = "arm,sp804", "arm,primecell";
- reg = <0xfc800000 0x1000>;
- interrupts = <0 0 4>, <0 1 4>;
- clocks = <&timclk1 &timclk2 &pclk>;
- clock-names = "timer1", "timer2", "apb_pclk";
- };
|