1234567891011121314151617181920212223242526272829303132333435363738394041424344 |
- Marvell Armada 370 and Armada XP Timers
- ---------------------------------------
- Required properties:
- - compatible: Should be one of the following
- "marvell,armada-370-timer",
- "marvell,armada-375-timer",
- "marvell,armada-xp-timer".
- - interrupts: Should contain the list of Global Timer interrupts and
- then local timer interrupts
- - reg: Should contain location and length for timers register. First
- pair for the Global Timer registers, second pair for the
- local/private timers.
- Clocks required for compatible = "marvell,armada-370-timer":
- - clocks : Must contain a single entry describing the clock input
- Clocks required for compatibles = "marvell,armada-xp-timer",
- "marvell,armada-375-timer":
- - clocks : Must contain an entry for each entry in clock-names.
- - clock-names : Must include the following entries:
- "nbclk" (L2/coherency fabric clock),
- "fixed" (Reference 25 MHz fixed-clock).
- Examples:
- - Armada 370:
- timer {
- compatible = "marvell,armada-370-timer";
- reg = <0x20300 0x30>, <0x21040 0x30>;
- interrupts = <37>, <38>, <39>, <40>, <5>, <6>;
- clocks = <&coreclk 2>;
- };
- - Armada XP:
- timer {
- compatible = "marvell,armada-xp-timer";
- reg = <0x20300 0x30>, <0x21040 0x30>;
- interrupts = <37>, <38>, <39>, <40>, <5>, <6>;
- clocks = <&coreclk 2>, <&refclk>;
- clock-names = "nbclk", "fixed";
- };
|