sysfs-bus-iio-adc-ad7280a 958 B

123456789101112131415161718192021
  1. What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_switch_en
  2. KernelVersion: 3.0.0
  3. Contact: linux-iio@vger.kernel.org
  4. Description:
  5. Writing 1 enables the cell balance output switch corresponding
  6. to input Y. Writing 0 disables it. If the inY-inZ_balance_timer
  7. is set to a none zero value, the corresponding switch will
  8. enable for the programmed amount of time, before it
  9. automatically disables.
  10. What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_timer
  11. KernelVersion: 3.0.0
  12. Contact: linux-iio@vger.kernel.org
  13. Description:
  14. The inY-inZ_balance_timer file allows the user to program
  15. individual times for each cell balance output. The AD7280A
  16. allows the user to set the timer to a value from 0 minutes to
  17. 36.9 minutes. The resolution of the timer is 71.5 sec.
  18. The value written is the on-time in milliseconds. When the
  19. timer value is set 0, the timer is disabled. The cell balance
  20. outputs are controlled only by inY-inZ_balance_switch_en.